Pipette Volume Ranges: P2, P20, P200, P1000 and More

Micropipette volume ranges

Laboratories usually stock a small set of air-displacement bodies whose nominal ranges overlap common P20 / P200 / P1000 work. Exact min/max is printed on the pipette; this page does not invent a calibration table.

How to read a range

The useful range is the interval printed on the pipette, not a nickname. “P20” in lab speech usually means a micropipette whose upper mark is 20 µL, but always confirm the scale on the instrument and in the SOP.

How labs typically cover a bench

Range chart: Gilson PIPETMAN Classic models P2 to P1000, the volume range listed in the manufacturer accuracy table and the tip specified for it; values are in the table below.Example from one manufacturer (Gilson): volume range and specified tip by modelPIPETMAN Classic. Log volume scale, µL. Range = volumes listed in the manufacturer’s accuracy table.0.1 µL1 µL10 µL100 µL1000 µLP20.2–2 µLTip: D10 / DL10P101–10 µLTip: D10 / DL10P202–20 µLTip: D200P10020–100 µLTip: D200P20050–200 µLTip: D200 / D300P1000200–1000 µLTip: D1000 / D1200Example from one manufacturer; not a brand recommendation. Check your own pipette’s documentation.
Example from one manufacturer (Gilson PIPETMAN Classic)
ModelVolume range in accuracy table, µLTip specified by manufacturer
P20.2–2D10 / DL10
P101–10D10 / DL10
P202–20D200
P10020–100D200
P20050–200D200 / D300
P1000200–1000D1000 / D1200
Example from one manufacturer (Gilson), not a brand recommendation. Source: Gilson PIPETMAN Classic User’s Guide LT801120/F (2017, PDF), maximum permissible errors table; performance is specified with Gilson PIPETMAN DIAMOND tips. Check your own pipette’s documentation.
  • Low-volume body for single-digit and low-teen microlitres
  • Mid-volume body around the 20–200 µL band
  • High-volume body around the 100–1000 µL band

Overlap is normal. Do not run a pipette at the extreme bottom of its scale when a smaller body exists — precision usually degrades there. For a buying list, send the volumes you actually pipette, not a brand slogan.

Tips must match the body

A P1000 tip on a P20 body is not a workaround. Specify tip length/filter needs with the volume range in the RFQ.

Related pipette pages

Need pipettes or matching tips for a lab buy?

Send volume range, tip type, and quantity. NIITO replies on the RFQ — manufacturer contacts stay off this page.

FAQ

Where are the ISO 8655 numeric limits?

On the calibration certificate and in ISO 8655 for the pipette’s nominal volume. This page does not reprint a guessed table.

Should I buy one pipette for every volume?

Usually no. Cover the bench with a small overlapping set and calibrate that set.